戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。
型號(hào) | 美國(guó)戴安 P/N: 076225 |
---|---|
廠商性質(zhì) | 代理商 |
更新日期 | 2018-05-02 |
Acclaim Explosives Columns: A Total Solution for EPA Method 8330
The Thermo Scientific Acclaim? Explosives E1 (5 ?m) and E2 (5, 3 and 2.2 μm) silica-based reversed-phase columns are designed to resolve all 14 explosives listed in EPA SW-846 Method 8330: Nitroaromatics and Nitramines by HPLC. Their unique chemistries deliver superior resolution with complementary selectivities. The E1 is recommended for use as a direct replacement for ODS columns for the primary analysis.The E2 may be used as either a primary or a confirmatory column.
The Acclaim Explosives stationary phases are based on ultrahigh-purity spherical silica gel particles, with 120 ? pore size. The Acclaim Explosives E1 is available in a 5 ?m particle size and E2 columns are available in 5, 3 and 2.2 μm particle sizes. The unique chemistry of these columns offers exceptional selectivity and stability over the range of pH 3.0 to 7.0, and their design ensures good column life and easy cleanup.
While both columns perform reproducibly under their optimized conditions, separation conditions for the Acclaim Explosives E2 can be readily changed to accommodate inclusion of additional explosives compounds.
The manufacturing process is controlled to ensure that every Explosives column delivers reproducible performance, lot-to-lot and column-to-column. The columns are tested for baseline resolution of all 14 explosives.
技術(shù)參數(shù):
Acclaim Explosives Columns — A Total Solution for EPA Method 8330 Specifications | |
---|---|
Starting Material | Ultra-pure silica |
Particle Size | 3 ?m and 5 ?m |
Particle Shape | Spherical |
Particle Size Distribution (40/90) | < 1.3 |
Metal Impurity (Na, Fe, Al) | <10.0 ppm Total Metal < 3.0 ppm Individual Metals |
Pore Volume | 0.9 - 1.0 mL/g |
Average Pore Diameter | 120 ? |
Surface Area | 300 m2/g |
Recommended pH range | 3.0 - 7.0 |
Temperature Limit | 50 oC |
訂購(gòu)信息:
Analytical Columns | |
---|---|
Acclaim RSLC Explosives E2, 2.2?m Analytical (2.1 x 100mm) | 076225 |
Acclaim RSLC Explosives E2, 2.2?m Analytical (2.1 x 150mm) | 076226 |
Acclaim RSLC Explosives E2, 2.2?m Analytical (3.0 x 100mm) | 076227 |
Acclaim Explosive E2, 3 ?m, Analytical, (2.1 x 150 mm) | 070083 |
Acclaim Explosive E2, 3 ?m, Analytical, (3.0 x 150 mm) | 070082 |
Acclaim Explosive E2, 3 ?m, Analytical, (3.0 x 250 mm) | 070081 |
Acclaim Explosives E1 (4.6 x 250 mm) | 064305 |
Acclaim Explosives E2 (4.6 x 250 mm) | 064309 |
Acclaim Explosives Kit (includes 064305, 064309, 064303, 064307; requires holder 059456) | 064312 |
Guard Columns | |
---|---|
Acclaim Explosives E1, 5 ?m Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069702 |
Acclaim E2, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 | 071989 |
Acclaim Explosives E2, 5 ?m Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069703 |
Acclaim SST Guard Cartridge Holder V-2 | 069580 |
Acclaim Guard Kit (Holder and coupler) V-2 | 069707 |
Guard to Analytical Column Coupler V-2 | 074188 |
Acclaim Explosive E1 Guard (4.3 x 10 mm), 2 ea; requires holder 059456 | 064303 |
Acclaim Explosive E2 Guard (4.3 x 10 mm), 2ea; requires holder 059456 | 064307 |
Acclaim SST Guard Cartridge Holder V-1 | 059456 |
Guard to Analytical Column Coupler | 059457 |
Guard Kit (Holder and Coupler) | 059526 |