久久精品国产精品亚洲艾-亚洲不卡精品在线观看-夜夜嗨av一区二区精品-欧美日韩视频在线观看一区二区

產(chǎn)品展示
PRODUCT DISPLAY

打印當(dāng)前頁(yè)

免費(fèi)咨詢:021-67610176

發(fā)郵件給我們:market@hsiyen.cn

分享到:
產(chǎn)品展示您現(xiàn)在的位置: 首頁(yè) > 產(chǎn)品展示 > > 美國(guó)戴安Dionex > 美國(guó)戴安SP5513Dionex ProPac SCX and WCX Protein Column 生物色譜柱

Dionex ProPac SCX and WCX Protein Column 生物色譜柱

簡(jiǎn)要描述:

戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。   
戴安公司的快速溶劑萃取儀15分鐘之內(nèi)僅用15毫升溶劑既可完成對(duì)10g樣品的萃取,該技術(shù)已在環(huán)境、藥物、食品和聚合物工業(yè)等領(lǐng)域得到廣泛應(yīng)用。

型號(hào) 美國(guó)戴安SP5513
廠商性質(zhì) 代理商
更新日期 2018-04-16

Strong and Weak Cation-Exchange Columns 

for High-Resolution Separation of Proteins and MAbs

New! The Thermo Scientific ProPac? SCX column line has expanded to include the next generation ProPac SCX-20 column. This column provides unequalled high resolution of protein variants.

Please also see the Thermo Scientific MAbPac? SCX-10 column, a strong cation-exchange column designed specifically for high-resolution, high-efficiency analysis of monoclonal antibodies (MAbs) and associated variants. This column is complimentary to the industry-leading ProPac WCX-10 column for monoclonal antibody variant analysis. The MAbPac SCX-10 offers an alternative selectivity and provides higher resolution and efficiency for variant analysis of most monoclonal antibody samples than the ProPac WCX-10 column.

ProPac SCX-10 and WCX-10 strong and weak cation-exchange columns are based on a nonporous core particle that results in high-efficiency peaks and high-resolution separations of protein variants. A hydrophilic layer prevents unwanted secondary interactions. A grafted cation-exchange surface provides pH-based selectivity control and fast mass transfer for high-efficiency separation and moderate capacity.

  • Characterization and quality control assessment of monoclonal antibodies and other proteins
  • Unequalled resolution
  • High-resolution separations with excellent sample recovery
  • Unmatched column-to-column and lot-to-lot reproducibility
  • Useful for characterization of related protein variants (e.g., deamidation and MAb lysine truncation variants)
  • Highly-efficient peaks with excellent sample recovery
  • Available in different dimensions and formats for flexibility in method development

The ProPac SCX-10 is a strong cation-exchange column with sulfonate functional groups, and the ProPac WCX-10 column has a carboxylate functional group. Both are based on 10 ?m nonporous, polymeric beads and coated with a proprietary hydrophilic layer.

All ProPac columns are manufactured and tested under the strictest specifications, resulting in unmatched column-to-column and lot-to-lot reproducibility. These columns are available as lot-select packages containing three columns from a single lot or three columns from three different lots, to assist quality control scientists in method validation.

ProPac SCX-10 Strong Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms  Specifications
Maximum operating pressure3000 psi (21 MPa)
Maximum operating temperature60 °C
Recommended operating temperature: <40 °C
Typical operating conditionsUV detection at 1 mL/min
Recommended flow rate: 1 mL/min
phase compatibilitypH 2–12; 80% compatible with acetonitrile, acetone, methanol.
Compatible with nonionic and zwitterionic detergents.
Incompatible with cationic detergents.
Resin composition10-?m-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the sulfonate functional groups.
Anion-exchange capacity< 100 ?g protein on-column, depending upon the protein
(4 × 250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
ProPac WCX-10 Weak Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms  Specifications
Resin composition10-?m-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the carboxylate functional groups.
Anion-exchange capacity< 100 ?g protein on-column, depending upon the protein
(4 × 250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Maximum operating pressure3000 psi (21 MPa)
Maximum operating temperature60 °C
Recommended operating temperature: <40 °C
Typical operating conditionsUV detection at 1 mL/min
Recommended flow rate: 1 mL/min
phase compatibilitypH 2–12; 80% compatible with acetonitrile and acetone.
Compatible with nonionic and zwitterionic detergents.
Incompatible with cationic detergents.
SCX Analytical Columns
ProPac SCX-20 Analytical Column (4 x 250 mm)074628
ProPac SCX-10 Analytical Column (4 x 250 mm)054995
ProPac SCX-10 Analytical Column (2 x 250 mm)063456
ProPac SCX-10 Semi-Preparative Column (9 x 250 mm)063700
ProPac SCX-10 Semi-Preparative Column (22 x 250 mm)SP5522
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin)SP5727
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin)SP5728
SCX Guard Columns
ProPac SCX-20 Guard Column (4 x 50mm)074643
ProPac SCX-10G Guard Column (4 x 50 mm)079930
ProPac SCX-10G Guard Column (2 x 50 mm)063462
WCX Analytical Columns
ProPac WCX-10HT Analytical Column (4x 50mm)074600
ProPac WCX-10 Analytical Column (4 x 100 mm)SP5829
ProPac WCX-10 Analytical Column (4 x 150 mm)SP6703
ProPac WCX-10 Analytical Column (4 x 250 mm)054993
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (1 Lot of Resin)SP5512
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (3 Lots of Resin)SP5513
ProPac WCX-10 Analytical Column (2 x 250 mm)063472
ProPac WCX-10 Semi-Preparative Column (9 x 250 mm)063474
ProPac WCX-10 Semi-Preparative Column (22 x 250 mm)SP5482
WCX Guard Columns
ProPac WCX-10G Guard Column (2 x 50 mm)063480
ProPac WCX-10G Guard Column (4 x 50 mm)054994

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7